TBX62DFC Tools&Cert LED/OM220A/OS420FC/OS430FC |
|
|
|
The Tools&Certification set contains everything needed to be a
complete package for the installer or the technician of fiber
optic cables. This set contains the tools to terminate and
polish SC, ST or FC connectors, a microscope for inspecting the
connectors, a power meter with an intern memory for 500
measurements, a source and software for documentation. The test
set includes the following products:
OM220A
The meter is a general-purpose power meter suitable for a both
premise and outside plant applications. The meter is suitable
for both single-mode and multimode applications, depending on
the source which is used.The
meter has an user selectable choice of 0,1 or 0,01 dB
resolution, on board memory for 500 readings with date and time
stamp, a serial port and an USB port for communication with a
PC. The included PC software easily download and document the
measurement results stored in the memory. The results can be
printed directly from the software or can be saved in a
spreadsheet file. These features make of the meter a perfect
certification tool.The meter measures optical power, loss
(attenuation) and optical return loss. The meter is calibrated
at industry standard wavelengths (NIST traceable). The zero
reference function is ideal for testing fiber optic cables in
dB, the reference value is saved in the power meter. A universal
2,5 mm universal adapter with a threaded housing is included,
other adapters are also available as an accessory. Due to the
backlight the data is always visible. The meter is delivered in
a protective rubber boot.
OS420FC
The sender is for premises and campus cabling networks with
multimode fiber or for single-mode fibers up to 5 km at 1300 nm.
The connector output can be adapted to any cable plant with
hybrid adapters or hybrid cables. This unit is easy to operate
with only a wavelength/power switch, which selects optical
wavelengths or disables the unit. The light source is designed
for performing insertion loss measurements on fiber optic links
when used with an optical power meter. Whether testing outside
plant or premise an optical source is the perfect tool when
combinated with an optical power meter. The output is stabilized
to ensure accurate test results per current TIA/EIA
requirements. The wavelengths are individually adjustable with a
mechanical screw to have a variable attenuator or to reduce the
output power. This make it able to save battery power when high
optical output power is not necessary, or to turn up the power
to test long runs. The sender is delivered in a protective
rubber boot.
OS430FC
The sender is for outside plant and single-mode fiber. The
connector output can be adapted to any cable plant with hybrid
adapters or hybrid cables. This unit is easy to operate with a
wavelength/power switch, which selects optical wavelengths or
disables the unit. There is also a switch which select between
either the CW or 2 kHz output for the transmitting
wavelength. The light source is designed for performing insertion
loss measurements on fiber optic links when used with an optical
power meter. Whether testing outside plant or premise an optical
source is the perfect tool when combinated with an optical power
meter. The output is stabilized to ensure accurate test results
per current TIA/EIA requirements. The wavelengths are
individually adjustable with a mechanical screw to have a
variable attenuator or to reduce the output power. This make it
able to save battery power when high optical output power is not
necessary, or to turn up the power to test long runs. The sender
is delivered in a protective rubber boot.
|
|
Features |
|
TBX62DFC Features: |
l |
Complete tool package for FC, SC and ST
connectors |
l |
Microscope |
l |
Power meter with an intern memory for 500
measurements |
l |
Source |
l |
Software for documentation |
|
TBX62DFC Package
Contents: |
1 |
OM220A |
1 |
OS420FC |
1 |
OS430FC |
1 |
AD120 (FC) |
1 |
SmartWare V3.00 |
1 |
CBL100 (OM-2xx to Serial Cable) |
1 |
CBL200 (Serial to USB Cable) |
1 |
Product Manual |
1 |
CALM Calibration Meter |
1 |
CALS Calibration
Sender |
1 |
Trim
Tool |
4 |
Alco
Wipe |
1 |
Safety Glasses |
1 |
Scribe |
1 |
Armored Tube Cutter |
1 |
Fiber Optic Stripper |
1 |
Buffer Tube Stripper |
1 |
Rotary Cable Stripper |
1 |
Crimp Tool |
1 |
Needle Nose Pliers |
1 |
Polishing Plate |
1 |
Polishing Puck |
1 |
Polishing Pad |
1 |
Tweezers |
1 |
Kevlar Scissors |
1 |
FCT100 (Continuity Tester) |
1 |
MSP200XP (Microscope) |
|
TBX62DFC Package
Contents: |
|
- See
options list |
|
|
Specifications |
|
OM220A (GP APPLICATIONS) |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Multimode,
Single-mode, Outside Plant and Premise |
Calibrated (λ)Wavelength |
850nm, 1300nm, 1310nm, 1490nm & 1550nm |
Dynamic Range |
+3 dBm to -55 dBm |
Detector Type |
2mm Germanium in
Modular Housing |
|
ST, SC, FC |
|
See
options list |
Accuracy (@25°C, -20.0 dBm) |
±0.25 dB |
Measurement Units |
dBm/mW (absolute) -
dB (relative) |
Resolution |
0.1 dB or 0.01
User Selectable |
Storage |
500 Readings with
Time and Date Stamp |
Serial Interface |
Yes |
USB Interface |
Yes |
PC Software |
Documentation
Software |
|
7 Soft Buttons |
|
On/Off, Backlight,
λ/↑,
dB-dBm/↓, Zero Reference/Select, Save/Delete,
Test/Results |
|
2x AA Batteries
or AC Power Converter |
|
Yes |
|
Graphical LCD with
Backlight |
|
Yes |
Protective rubber boot |
Yes |
Testing reference guide |
Yes |
|
L: 125 mm W: 70 mm H: 30mm |
|
230 Grams |
|
-10°C to +50°C
(45% Hum, non condensing) |
|
-20°C to +60°C
(75% Hum, non condensing) |
|
OS420FC (Multimode APPLICATIONS) |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Permise cable networks with multimode fiber |
Wavelength (λ) |
850 nm and 1300 nm |
Output type |
LED |
Modulated Frequencies |
CW (Continuous Wave) |
Stability, 1 hour |
Less than 0.05 dB |
Power Output |
>-17 dBM, individually adjustable with mechanical screw |
Connector |
FC |
Controls |
Front panelslide switches |
Power |
2 AA Batteries or AC Power Converter |
Low battery indicator |
Yes |
Protective rubber boot |
Yes |
Enclosure Size |
L: 125 mm, W: 70 mm, H: 30 mm |
Weight |
180 gram |
Operation Temperature |
-10°C to +50°C (45% Hum, non condensing) |
Storage Temperature |
-20°C to +60°C (75% Hum, non condensing) |
|
OS430FC (Single mode APPLICATIONS) |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Outside plant single mode |
Wavelength (λ) |
1310 nm and 1550 nm |
Output type |
Laser |
Modulated
Frequencies |
2 kHz/CW (Continuous Wave) |
Stability, 1 hour |
Less than 0.05 dB |
Power Output |
>-8 dBm, individually adjustable with mechanical screw |
Connector |
FC |
Controls |
Front panel slide switches |
Power |
2 x AA Batteries
or AC Power Converter |
Low battery indicator |
Yes |
Protective rubber boot |
Yes |
Enclosure Size |
L: 125 mm, W: 70 mm, H:30 mm |
Weight |
Compact Handheld;
L 12,55 cm x W 6,99 cm x H 3,05 cm |
Operation Temperature |
-10°C to +50°C (45% Hum, non condensing) |
Storage Temperature |
-20°C to +60°C (75% Hum, non condensing) |
|
|
OM200A Reporter software specifications |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Number of
measurements |
500 measurements |
User information |
Company name |
|
Phone number |
|
Name |
|
Job
ID |
Fiber parameters |
User fiber ID |
|
Fiber type |
|
Fiber details |
|
Connector type |
Meter readings |
Model meter |
|
Calibration date |
|
Reading ID |
|
Result |
|
NanoWatt |
|
dB/dBm |
|
Wavelength |
|
Time and date |
Meter fiber
parameters |
Fiber length (km) |
|
Number of
connectors |
|
Number of splices |
Fiber analyse
results |
Wavelength |
|
Actual reading |
|
Allowable loss |
|
Overhead margin |
|
Pass/fail |
Qualified |