OLK63AXPSMFC Cert.Set CATV
OM230A/OS430FC/MSP200XP |
|
|
|
This
certification test set is the complete solution necessary for
the installer to certify, test, terminate, trouble shoot and
document fiber optic systems. The test set is designed to allow
testing of all parameters of fiber optic networks, including
output power levels from the fiber, coupled source power and
attenuation loss in a fiber.
The test
set includes the following products:
OM230A
The meter is designed for high power optical systems and CATV
applications. The meter optimizes a high power Germanium
detector.
The meter has an user selectable choice of 0,1 or 0,01 dB
resolution, on board memory for 500 readings with date and time
stamp, a serial port and an USB port for communication with a
PC.
In the internal memory of the meter 500 readings and results can
be stored. The included PC software easily download and document
the measurement results stored in the memory. The results can be
printed directly in detail or as list from the software or can
be saved in a spreadsheet file.
The meter measures optical power, loss
(attenuation) and optical return loss. The meter is calibrated
at industry standard wavelengths (NIST traceable). The zero
reference function is ideal for testing fiber optic cables in
dB, the reference value is saved in the power meter. A universal
2,5 mm universal adapter with a threaded housing is included,
other adapters are also available as an accessory. Due to the
backlight the data is always visible. The meter is delivered in
a protective rubber boot.
OS430FC
The sender is for outside plant and single-mode fiber. The
connector output can be adapted to any cable plant with hybrid
adapters or hybrid cables. This unit is easy to operate with a
wavelength/power switch, which selects optical wavelengths or
disables the unit. There is also a switch which select between
either the CW or 2 kHz output for the transmitting
wavelength. The light source is designed for performing insertion
loss measurements on fiber optic links when used with an optical
power meter. Whether testing outside plant or premise an optical
source is the perfect tool when combined with an optical power
meter. The output is stabilized to ensure accurate test results
per current TIA/EIA requirements. The wavelengths are
individually adjustable with a mechanical screw to have a
variable attenuator or to reduce the output power. This make it
able to save battery power when high optical output power is not
necessary, or to turn up the power to test long runs. The sender
is delivered in a protective rubber boot.
MSP200XP
The
MSP200XP is
a high-resolution glass optics scope with 200x magnification for
both multimode and single-mode fibers. The MSP200XP is portable
and is an ideal field tool for inspecting fiber terminations.
The Fiber Microscope utilizes a white LED for coaxial
illumination. Light is focused into the optical path (axis) so
that it comes out the tip of the ferrule and strikes the sample
perpendicular to the fiber end-face. It produces excellent
detail of scratches and contamination. The MSP200XP is equipped
with an attenuating, laser safety filter to reduce the risk of
eye damage when the user accidentally views a fiber with active
emissions. The MSP200XP is equipped with a standard 2,5 mm
adapter, optional is an 1,25 mm adapter. |
|
Features |
|
OLK63AXPSMFC Package Contents: |
1 |
OM230A |
1 |
OS430FC |
1 |
MSP200XP |
1 |
AD120 (FC) |
1 |
SmartWare V3.00 |
1 |
CBL100 (OM-2xx
to Serial Cable) |
1 |
CBL200 (Serial
to USB Cable) |
2 |
Product Manual |
1 |
CALM Calibration Meter |
1 |
CALS Calibration
Sender |
1 |
Trim Tool |
4 |
Alco Wipe |
|
OLK63AXPSMFC Options: |
|
- See
options list |
|
|
Specifications |
|
OM230A (POF APPLICATIONS) |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Single-mode, Long wavelengths, CATV |
Calibrated (λ)Wavelength |
1310nm and 1550nm |
Dynamic Range |
+20 dBm to -30 dBm |
Detector Type |
High Powered Germanium in Modular Housing |
Connectors |
ST, SC, FC |
Adaptor Options |
See
options list |
Accuracy (@25°C, -20.0 dBm) |
±0.25 dB |
Measurement Units |
dBm (absolute) - dB (relative) |
Resolution |
0.1 dB or 0.01 User Selectable |
Storage |
500 Readings with Time and Date Stamp |
Serial Interface |
Yes |
USB Interface |
Yes |
PC Software |
Documentation Software |
Controls |
7 Soft Buttons |
Buttons |
On/Off, Backlight, λ/↑, dB-dBm/↓, Zero Reference/Select,
Save/Delete, Test/Results |
Power |
2 AA Batteries or AC Power Converter |
Low Battery Indicator |
Yes |
Display |
Graphical LCD with Backlight |
Auto-Shutdown |
Yes |
Protective rubber boot |
Yes |
Testing reference guide |
Yes |
Enclosure Size |
Compact Handheld (L-4.94"/W-2.75"/H-1.2") |
Weight |
230 gram |
Operation Temperature |
-10°C to +50°C (45% Hum, non condensing) |
Storage Temperature |
-20°C to +60°C (75% Hum, non condensing) |
|
OS430FC (Single mode APPLICATIONS) |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Outside plant single mode |
Wavelength (λ) |
1310 nm and 1550 nm |
Output type |
Laser |
Modulated
Frequencies |
2 kHz/CW (Continuous Wave) |
Stability, 1 hour |
Less than 0.05 dB |
Power Output |
>-8 dBm, individually adjustable with mechanical screw |
Connector |
FC |
Controls |
Front panel slide switches |
Power |
2 x AA Batteries
or AC Power Converter |
Low battery indicator |
Yes |
Protective rubber boot |
Yes |
Enclosure Size |
L: 125 mm, W: 70 mm, H:30 mm |
Weight |
Compact Handheld;
L 12,55 cm x W 6,99 cm x H 3,05 cm |
Operation Temperature |
-10°C to +50°C (45% Hum, non condensing) |
Storage Temperature |
-20°C to +60°C (75% Hum, non condensing) |
|
|
MSP200XP |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Multimode and Single mode |
Optical Magnification |
200x |
LED |
Rated life 100,000 Hrs |
Controls |
Momentary On/Off switch, Fine-Focus control |
Safety Filter |
Built in IR filter |
Adapter
Interface |
2,5 mm universal standard – optional
1,25 mm available |
Power Requirements |
3 pieces 1,5 Volt AAA alkaline Batteries |
Size |
L: 225 mm, Diameter 32 mm |
Weight |
0.6Kg |
|
OM200A Reporter software specifications |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Number of
measurements |
500 measurements |
User information |
Company name |
|
Phone number |
|
Name |
|
Job
ID |
Fiber parameters |
User fiber ID |
|
Fiber type |
|
Fiber details |
|
Connector type |
Meter readings |
Model meter |
|
Calibration date |
|
Reading ID |
|
Result |
|
NanoWatt |
|
dB/dBm |
|
Wavelength |
|
Time and date |
Meter fiber
parameters |
Fiber length (km) |
|
Number of
connectors |
|
Number of splices |
Fiber analyse
results |
Wavelength |
|
Actual reading |
|
Allowable loss |
|
Overhead margin |
|
Pass/fail |
Qualified |
CE, RoHS and WEEE |
|
|